CLAMP METER WITH DIGITAL TESTER

1800164

  • Current peak measurement
  • Duty-cycle: percentage of the active signal over the total period
  • Batteries included.

CHARACTER HEIGHT

17

audio alert

SI

digital reading

SI

data memory

SI

capacity measure

SI

frequency measure

SI

resistance measure

SI

flow rate frequency

40 MHz

overload prot.

NO

automatic scale

SI

thermal probe

SI

diode test

SI

transistor test

NO

thermocouple type

K

field + high f.d.s.

1000A

field + high e.o.s.

10mF

field + high e.o.s.

1000A

field + high f.d.s.

40Mohm

field + high e.o.s.

+301°+1000°

field + high e.o.s.

700V

field + high f.d.s.

1000V

field +low s.d.f.

400A

field +low s.d.f.

10nF

field +low s.d.f.

400A

field +low s.f.

400ohm

field +low s.d.f.

-50°+300°

field +low s.d.f.

400mV

field +low s.d.f.

400mV

nr fields of measure.

2

nr of meas. fields.

7

nr of meas fields.

2

nr of meas fields.

6

nr fields of measure.

5

nr fields of measure.

5

nr fields of meas.

7

maximum precision

+-2%/+-5DGT

maximum precision

+-3%/+5DGT

maximum precision

+-2%/+5DGT

maximum precision

+-1%/+3DGT

max precision

+-1%+-5DGT

max precision

+-1,2%/+-5DGT

maximum precision

+-0,8%/+2DGT

max precision

+-0,5%/+-3DGT

resolution

1A

resolution

100mA

resolution

1uF

resolution

0,001nF

resolution

1A

resolution

100mA

resolution

0,1ohm

resolution

10kohm

resolution

resolution

resolution

1V

resolution

0,1mV

resolution

1V

resolution

0,1mV

Catalog Image

Download IMG

Instruction Manual

Download PDF

  • Current peak measurement
  • Duty-cycle: percentage of the active signal over the total period
  • Batteries included.

CHARACTER HEIGHT

17

audio alert

SI

digital reading

SI

data memory

SI

capacity measure

SI

frequency measure

SI

resistance measure

SI

flow rate frequency

40 MHz

overload prot.

NO

automatic scale

SI

thermal probe

SI

diode test

SI

transistor test

NO

thermocouple type

K

field + high f.d.s.

1000A

field + high e.o.s.

10mF

field + high e.o.s.

1000A

field + high f.d.s.

40Mohm

field + high e.o.s.

+301°+1000°

field + high e.o.s.

700V

field + high f.d.s.

1000V

field +low s.d.f.

400A

field +low s.d.f.

10nF

field +low s.d.f.

400A

field +low s.f.

400ohm

field +low s.d.f.

-50°+300°

field +low s.d.f.

400mV

field +low s.d.f.

400mV

nr fields of measure.

2

nr of meas. fields.

7

nr of meas fields.

2

nr of meas fields.

6

nr fields of measure.

5

nr fields of measure.

5

nr fields of meas.

7

maximum precision

+-2%/+-5DGT

maximum precision

+-3%/+5DGT

maximum precision

+-2%/+5DGT

maximum precision

+-1%/+3DGT

max precision

+-1%+-5DGT

max precision

+-1,2%/+-5DGT

maximum precision

+-0,8%/+2DGT

max precision

+-0,5%/+-3DGT

resolution

1A

resolution

100mA

resolution

1uF

resolution

0,001nF

resolution

1A

resolution

100mA

resolution

0,1ohm

resolution

10kohm

resolution

resolution

resolution

1V

resolution

0,1mV

resolution

1V

resolution

0,1mV

Catalog Image

Download IMG

Instruction Manual

Download PDF